2CHAPTER 1OverviewThis chapter provides an overview of UNO-4672’s specifications.Sections include:• Introduction• Hardware Specifications• Safety P
UNO-4672 User Manual 2Chapter 1 Overview1.1 IntroductionUNO-4672 is an embedded Application Ready Platform (ARP) that can shorten development time a
3 Chapter 1 Robust IO Isolate System from Electrical NoiseUNO-4672 is designed for the applications in substation where is sup-posed to have certain
UNO-4672 User Manual 4Popular Operating Systems and Rapid Application DevelopmentThe Advantech UNO-4672 supports the popular off-the-shelf Microsoft W
5 Chapter 1 1.2 Hardware SpecificationsGeneralCertifications IEC-61850-3, CE, FCC Class ADimensions (W x D x H) 2U (440 x 220 x 88 mm) (17.3” x 8.6
UNO-4672 User Manual 6I/O InterfaceSerial Ports 2 x DB-9 connectors with 9-wired RS-2328 x screw terminals with 5-wired RS-232/422/485 selectableAutom
7 Chapter 1 EnvironmentHumidity 95% @ 40° C (non-condensing)Operating Temperature -20 ~ 55° C (-4 ~ 131° F) (100% CPU load)-20 ~ 65°C (-4 ~ 149°
UNO-4672 User Manual 81.4 Chassis DimensionsFigure 1.1: Chassis Dimensions1.5 Packing ListThe accessory package of UNO-4672 contains the following i
2CHAPTER 2Hardware FunctionalityThis chapter shows how to setup the UNO-4672’s hardware functions, including connecting peripherals, set-ting switches
UNO-4672 User Manual iiCopyrightThis document is copyrighted, © 2009. All rights are reserved. The origi-nal manufacturer reserves the right to make i
UNO-4672 User Manual 10Chapter 2 Hardware Functionality2.1 OverviewThe following two figures show the indicators and connectors on UNO-4672. The fol
11 Chapter 2 2.2 LED IndicatorsThe LEDs in the front panel can be divided into 4 groups.2.2.1 System Status IndicatorsTable 2.1: Definition of Syste
UNO-4672 User Manual 122.2.2 LAN Status Indicators2.2.3 Serial Communication Status Indicators Table 2.2: Definition of LAN Status IndicatorsItem LED
13 Chapter 2 2.2.4 Digital Input/Output Status Indicators2.3 Power InputThe UNO-4672 support AC/DC power input to fulfill the need of field site. Fo
UNO-4672 User Manual 14The function of each part is described as below:Table 2.6: AC/DC Power Input Function IntroductionItem Function Description1 Po
15 Chapter 2 2.4 RS-232 Interface (COM1,COM2)The UNO-4672 offers two standard RS-232 serial communication inter-face port: COM1 and COM2. Please ref
UNO-4672 User Manual 162.5.4 Terminal Resistor (JP9~JP16)The onboard termination resistor (120 ohm) for COM3~COM10 can be used for long distance trans
17 Chapter 2 Figure 2.3: COM Port Related Jumper/Switch Locations
UNO-4672 User Manual 182.5.5 RS-232/422/485 SelectionCOM3 ~ COM10 support RS-232, RS-422 and RS-485 interfaces. The system detects RS-422 or RS-485 si
19 Chapter 2 2.5.6 RS-485 Auto Flow & RS-422 Master/Slave ModesYou can set the “Auto Flow Control” mode of RS-485 or “Master/Slave” mode of RS-42
iiiProduct Warranty (2 years)Advantech warrants to you, the original purchaser, that each of its prod-ucts will be free from defects in materials and
UNO-4672 User Manual 202.6 LAN: Ethernet ConnectorThe UNO-4678 is equipped with 2 Intel 82541 PI Gigabit Ethernet Con-troller which are compliant wit
21 Chapter 2 2.7 USB PortsThe UNO-4672 provides four USB interface connectors, which provide complete Plug & Play and hot swapping for up to 127
UNO-4672 User Manual 222.9.1 Lithium Battery Specifications• Type: BR2032 (Using CR2032 is NOT recommended)• Output voltage: 3 VDC• Location: the b
23 Chapter 2 Figure 2.7: Digital Input Connector Pin Assignments2.10.2 Isolated InputsEach of isolated digital input channels accepts 0 ~ 50 VDC volt
UNO-4672 User Manual 24Figure 2.8: Isolated Digital Input Connection2.10.3 Interrupt Function of the DI SignalsDI0 and DI1 can be used to generate har
25 Chapter 2 2.10.5 Interrupt Control RegisterThe Interrupt Control Register controls the function and status of each interrupt signal source. Table
UNO-4672 User Manual 262.10.7 Interrupt Triggering Edge ControlThe interrupt can be triggered by a rising edge or a falling edge of the interrupt sign
27 Chapter 2 2.11 Onboard Isolated Digital OutputThe UNO-4672 has 8 isolated DO channels designated DO0 ~ DO7.2.11.1 Pin AssignmentsThe connector ty
UNO-4672 User Manual 282.11.2 Power On ConfigurationDefault configuration after power on or hardware reset is to set all the iso-lated digital output
29 Chapter 2 2.11.3 Isolated OutputsEach of isolated output channels comes equipped with a Darlington tran-sistor. All output channels share common e
UNO-4672 User Manual ivCEThis product has passed the CE test for environmental specifications. Test conditions for passing included the equipment bein
UNO-4672 User Manual 302.12 Onboard Isolated Counter/TimerThe UNO-4672 uses one 82C54 programmable timer/counter chip that includes three independent
31 Chapter 2 CTR0F/CTR1F: (Counter 0/1) interrupt flag bit CTR0Gate/CTR1Gate: (Counter 0/1) gate control bit CTR0Out /CTR1Out: (Counter 0/1) output s
UNO-4672 User Manual 322.12.2 Counter 0 Function BlockFigure 2.11: Counter 0 Function Block2.12.3 Counter 1 Function BlockFigure 2.12: Counter 1 Funct
33 Chapter 2 2.12.5 Counter Clock SourceThere are two clock sources available for the user counters by setting counter clock control bits - CTR0CLKSe
UNO-4672 User Manual 342.12.8 Counter Output DestinationYo u can choose the output destination of counter 0 and counter 1 by setting “Output Destinati
35 Chapter 2 2.12.10 Cascaded 32-bit CounterYou can also cascade counter 0 and counter 1 together as one 32-bit coun-ter/timer, and it’s configured b
UNO-4672 User Manual 36LEDEn: =0, DIAG LED disable=1, DIAG LED enableLEDS0 and LEDS1: LED flickering speed setting bit (refer to Table 2.16)SPKEn: =0
37 Chapter 2 2.14 PC/104+UNO-4672 supports standard PC/104+ version 1.2, which supports up to 3 PCI masters (CN11). You also could install jumper (C
UNO-4672 User Manual 38
2CHAPTER 3Initial Setup
vSafety Instructions1. Read these safety instructions carefully.2. Keep this User's Manual for later reference.3. Disconnect this equipment from
UNO-4672 User Manual 40Chapter 3 Initial Setup3.1 ConfigurationTo open the chassis, please follow the steps below:1. Remove all power and signal con
41 Chapter 3 3.2 Install a CompactFlash CardUNO-4672 provides 2 CompactFlash Card slots, to install the cards:1. Please follow 3.1 to open the chass
UNO-4672 User Manual 423.3 Installing a USB DongleUNO-4672 provides a clamp to fix the USB dongle which can be installed inside the chassis. Please f
43 Chapter 3 3. Adjust the position of the kit to fasten the USB dongle, and then screw to fix the kit.3.4 Installing a Hard DiskPlease follow the s
UNO-4672 User Manual 443. Insert the HDD into the HDD bay and screw it.4. Connect the SATA cable between HDD and connector then assem-ble the HDD back
45 Chapter 3 3.5 Installation on RackUNO-4672 provides the kits for Rack mounting in the accessory box. 1. Please screw the ears and handles at the
UNO-4672 User Manual 463.6 BIOS Setup and System AssignmentsUNO-4672 adopts Advantech's SOM-4486 and SOM-4481 CPU module. Further information ab
AppendixASystem Settings and Pin Assignments
UNO-4672 User Manual 48Appendix A System Settings & Pin AssignmentsA.1 System I/O Address & Interrupt AssignmentsTable A.1: UNO-4672 System
49 Appendix A Table A.2: UNO-4672 Interrupt AssignmentInterrupt No. Interrupt SourceNMI Parity error detectedIRQ 0 Interval timerIRQ 1 KeyboardIRQ 2
UNO-4672 User Manual vi20° C (-4° F) OR ABOVE 55° C (131° F). THIS COULD DAM-AGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT.16
UNO-4672 User Manual 50A.2 RS-232/422/485 Serial Ports (COM1~COM10)Table A.3: RS-232 Serial Ports COM1~2Pin RS-2321 DCD2RxD3TxD4DTR5GND6DSR7RTS8CTS9R
51 Appendix A Table A.4: RS-232/422/485 Serial Ports (COM3~10)Pins RS-232 RS-422 RS-4851RxD Tx+ Data+2TxD Tx- Data-3RTS Rx+ -4CTS Rx- -5 GND GND GND
UNO-4672 User Manual 52A.3 USB Connectors (USB1~USB2)A.4 VGA Display ConnectorTable A.5: USB Connector Pin AssignmentsPin Signal Name Cable Color1 V
53 Appendix A A.5 UNO-4672 Control Register * Refer to 82c54 manualTable A.7: UNO-4672 Control RegisterBase Address7 6 5 4 3 2 1 0 200H R Is
UNO-4672 User Manual 54
AppendixBProgramming the Watchdog Timer
UNO-4672 User Manual 56Appendix B Watchdog Timer Program-mingB.1 UNO-4672Below is a sample of programming code for controlling the WatchdogTimer fun
57 Appendix B OUT DX,ALMOV DX,2FHMOV AL,01H; 01:activate 00:inactivateOUT DX,AL;MOV DX,2EHMOV AL,F5H; Setting counter unit is secondOUT DX,ALMOV DX,2
UNO-4672 User Manual 58
AppendixCEnabling the Advantech 443 WDT
vii Table of ContentsContentsChapter 1 Overview ... 21.1 Introduction ...
UNO-4672 User Manual 60Appendix C Enabling the Advantech 443 WDTUNO-4672 reserves another set of Watchdog Timer for customer's special need. The
61 Appendix C C.2 Software OperationTo program the watchdog timer, you must write a program which writes I/O port address 443 (hex). The output data
UNO-4672 User Manual 62The following example shows how to program the watchdog timer in BASIC:10 REM Watchdog timer example program20 OUT &H443, d
UNO-4672 User Manual viii2.9 Battery Backup SRAM..... 212.9.1 Lithium Battery Specifications ...
ix Table of ContentsTable 2.25:32-bit Counter Control Bit ....... 352.13 LED and Buzzer for System Diagnosis.......
Comentários a estes Manuais