Compliance Certification Services Inc.
Report No.: 60707201-F Refer No.: 60321204 Date of Issue: July 7, 2006
Page 15 Rev. 00
Radiated Emission
Model: IPC-5120 Test Mode: Mode 1
Temperature: 20°C Humidity: 85% RH
Test Results: Passed Tested by: Mark Hsu
(The chart below shows the highest readings taken from the final data.)
Six Highest Radiated Emission Readings
Frequency Range Investigated 30 MHz to 1000 MHz at 10m
Freq.
MHz
Amptd
dBuV/m
Margin
dB
Limit
dBuV/m
Reading
dBuV
Factor
dB/m
Reading
Type
(P/Q/A)
Pol.
(H/V)
431.4200
37.72 -9.28 47.00 43.90 -6.18 Q V
499.7100
36.50 -10.50 47.00 41.10 -4.60 Q V
696.8600
37.17 -9.83 47.00 38.60 -1.43 Q V
497.8300
37.36 -9.64 47.00 42.00 -4.64 Q H
566.3300
36.96 -10.04 47.00 40.20 -3.24 Q H
696.8600
39.37 -7.63 47.00 40.80 -1.43 Q H
NOTE: 30MHz to 1000MHz test is Applicable CISPR 22 / EN 55022 standard.
Comentários a estes Manuais