The steps are repeated two more times to test 1.8
GHz GSM and GPRS signals.
Software takes care of switching from one test
mode to the next, so the operator simply places
mobile phones into the fixture, and listens to audio
signals to see if the phone passes the test. After the
three modes have been tested, the test results are
automatically stored in a database together with the
product’s serial number. The operator removes the
phones from the fixtures, and replaces them with
four new phones.
Before this system was implemented, the operator
would have to manually adjust the instrument to
the wanted frequency range. Then dial out using
the keypad of the mobile phone, and check if the
frequency was correct by reading the frequency
displayed on the instrument. The test data was then
entered into a database by hand. Obviously, there
was room for many human errors as one minute
was not much time to complete all the required
steps.
Although this solution is specific for mobile phones,
similar solutions can be used for testing PDAs,
CD-ROMs and other electronics. Together with
Advantech engineers, you can develop a customized
solution that removes the bottlenecks in your quality
test system.
Project Implementation
Agilent
®
8960 Test instrument with 2 frequency input channels
Conclusion
Increased output of approximately 1,200%
Fewer human errors with automated quality control
More efficient usage of equipment with one operator using four test stations and two instruments.
Scalability. The system diagram shows a system where the Agilent instruments are the bottleneck
as they only have two input channels. The cards currently in this system together with eight
instruments with two channels each would have a capacity of 16 phones
Adaptable; minor modifications can make the system capable of running many similar tests
Open standard; a variety of suppliers for all components in the solution
PCI-1762
Relay Actuator and Isolated D/I Card
PCI-1723
Non-isolated Analog Output Card
PCI-1670
GPIB Interface PCI-bus Card
Agilent 8960
Verify GSM, GPRS signal
Agilent 8960
Verify GSM, GPRS signal
Frequency
signal
GPIB
Relay
Output
Analog
Output
30