Advantech SOM-5786 Manual do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 60
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
11 Chapter 2
2.2.5 Terminal Resistor Setup for RS-422/485
The onboard termination resistor (120 Ohm) for COM1/COM2 can be
used for long distance transmission or device matching (Default Open).
Each terminal resistor responds to different channels for RS-422/485.
Usually, these resistors are needed for both ends of the communication
wires and the value of the resistors should match the characteristic imped-
ance of the wires used.
Table 2.1: Terminal Resistor Settings
COM Port Switch No. Pin Setting Description
COM1 SW4 1 ON 120 Ohm between Data+/
Data- (RS-485)
Or 120 Ohm between Tx+/Tx-
(RS-422)
OFF Open (Default)
2 ON 120 Ohm between Rx+/Rx-
(RS-422)
OFF Open (Default)
COM2 SW5 1 ON 120 Ohm between Data+/
Data- (RS-485)
Or 120 Ohm between Tx+/Tx-
(RS-422)
OFF Open (Default)
2 ON 120 Ohm between Rx+/Rx-
(RS-422)
OFF Open (Default)
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 59 60

Comentários a estes Manuais

Sem comentários