53 Appendix C
C.19 Reset all D/A channels strobe — BASE+22H
Write any values to BASE+22H to reset all D/A channels.
C.20 Reset the calibration controller strobe —
BASE+24H
Write any values to BASE+24H to reset the calibration controller.
C.21 Change D/A channels output strobe (BASE+26H)
Write any values to BASE+26H to change D/A channel output type.
Table C.20: Register for reset all D/A channels strobe
Base
Addr.
1514131211109876543210
22H W Reset all D/A channels strobe
XXXXXXXXXXXXXXXX
Table C.21: Reset the calibration controller strobe
Base
Addr.
1514131211109876543210
24H W Reset the calibration controller strobe
XXXXXXXXXXXXXXXX
Table C.22: Change D/A channels output type strobe
Base
Addr.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
26H W Change D/A channels output type strobe
XXXXXXXX XXXXXXXX
Note: Once you want to change the range of the
specific channel, be sure to write the value
to BASE+14H first. After that, write any
value to this register to strobe the change.