4.3.11 MAIVoltageInExp
Reads an analog input channel with an expansion board and returns the result scaled to a voltage in
units of volts. This function supports the expansion boards: PCLD-770/779/789/789D/788.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
MAIVoltageInExp A cluster containing NumChan, DasChanArray,
DasGainArray, ExpChanArray and VoltageArray
values
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type
Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
VoltageList Returns the value of a list of voltages.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in