4.6.4 CounterFreqRead
Reads the frequency measurement.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program..
Counter Counter number of the specified device.
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type
Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program..
Frequency Returned frequency value of the counter.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in