Compliance Certification Services Inc.
Report No.: 40614203-D Date of Issue: July 15, 2004
Page 17 Rev. 00
Line Conducted Emission
Model: PPC-V106 Test Mode: Mode 3
Temperature: 27°C
Humidity: 60% RH
Tested by: Carl Chang Test Results: Pass
(The chart below shows the highest readings taken from the final data)
L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)
Note: “---” denotes the emission level was or more than 2dB below the Average limit, so no re-check anymore.
Q.P. AVG Q.P. AVG Q.P. AVG
Raw Raw Limit Limit Margin Margin
(dBuV) (dBuV) (dBuV) (dBuV) (dB) (dB)
0.175 42.10 --- 64.72 54.72 -22.62 --- L1
1.326 23.60 --- 56.00 46.00 -32.40 --- L1
3.832 22.50 --- 56.00 46.00 -33.50 --- L1
5.326 30.50 --- 60.00 50.00 -29.50 --- L1
6.444 34.60 --- 60.00 50.00 -25.40 --- L1
8.006 36.20 --- 60.00 50.00 -23.80 --- L1
0.170 40.10 --- 64.96 54.96 -24.86 --- L2
1.436 26.30 --- 56.00 46.00 -29.70 --- L2
2.493 25.20 --- 56.00 46.00 -30.80 --- L2
5.366 30.70 --- 60.00 50.00 -29.30 --- L2
6.418 34.50 --- 60.00 50.00 -25.50 --- L2
8.245 37.40 --- 60.00 50.00 -22.60 --- L2
Freq.
(MHz)
NOTE